The Marine DIN-Rail Input/Output unit provides a voltage-free, single, pole, change-over relay output, a single monitored switch input, and an unmonitored, non-polarised opto-coupled input.
The Marine DIN-Rail Input/Output unit supervises one or more normaly-open switches connected to a single pair of cables. It is set to return an analogue value of 4 in the event of an open or short-circuit fault and 16 during normal operation. The status of the inputs is reported by means of two input bits.
The changeover contact is operated by a software command from the panel.
Certification: MED, ABS, VNIIPO & ESC
Loop Voltage | 17 - 28 VDC |
Maximum Current Consumption, at 28 V | |
Switch-On Surge | 3.5 mA |
Quiescent | 31.2 mA |
Input s/c Max (LED on) | 6 mA |
Short Circuit | 11 mA |
LEDs Disabled | 2.2 mA |
Any Other Condition | 4.5 mA |
Relay Current | 1A at 30 V dc |
Switch Input Monitoring Voltage | 9 - 11 V dc |
Operating Temperature | -20°C to +70°C |
Relative Humidity | 0 to 95% (no condensation or icing) |
IP Rating | Designed to IP20 |
Please Note: All data is supplied subject to change without notice. Specifications are typical at 24V, 23°C and 50% RH unless otherwise stated.
55000-774MAR | Marine Input/Output Unit |